A 2" schedule 40 conduit is included with the MO fixture and 1.5" is included with the PO fixture. Both are in a length of 12 inches. This conduit can be cut to length, but must always fully capture the fixture base.  The included conduit cannot be cut any shorter than 7–1/2", so if a shorter length is required, a standard 2" (MO) or 1.5" (PO) conduit can be used.  Insert the fixture module into the faceplate, and then press the complete assembly into the installed conduit. The module and faceplate must be fully pressed together to maintain proper seal. Ensure the faceplate is pressed as flush as possible to the mounting surface.

 

Fixture PO MO
Conduit Included 12" 12"
Conduit Included minumum length cut 7.5" 7.5"
 Conduit Sizes if SCH 40 used (optional) 1.5" 2"
Fixture Length (see figure 1.) 2 1/4" 2 1/4"
Exact Dimensions (Fixture Outside Diameter) 1.56" 2.01"

Suggested Mating (Outside Diameter with O-rings)

1.595" 2.05"

Conduit Outside Dimensions (see figure 2.)

1.909" 2.377"

 

 

For information on using the wall bracket with these fixtures, click on this link for install details:

Install Notes: PO and MO  

Install Bracket Notes: PO and MO 

 

 

 

 

 

 

 

 

 

 