Filter

LX - No Power on Low Voltage Terminals

Tabs

Read Article

If the LX transformer does not power on THE LOW VOLTAGE TERMINALS when plugged into a working outlet, the internal fuse may need to be replaced. NOTE: The front panel will still show power.  To protect the LX from ground surges caused by lightning or damaged connections, there is a buss fuse contained in the top of the transformer. This fuse does not protect the incoming voltage, just the low voltage side of the transformer.  The LX buss fuse is located in the top-wiring compartment of the LX lighting transformer. Replace with a UL Listed 3AG with the following specifications: 10 Amp – 250V.

This procedure should only be performed by a licensed electrician.  Disconnect power from the primary and secondary.

Step 1

Remove power by unplugging the transformer.  Use a flat bladed screw driver to remove cover.

Step 2

Twist the two sides of the fuse holder in opposite directions to open.

Step 3

Open fuse holder to change fuse.

Rate this Article: 
5
Average: 5 (1 vote)

Was this article helpful? Yes | No