Read Article

Before programming, determine which WIRELESS LUXOR LINKING (LINK-MOD) will be installed on the primary Luxor Controller (LUX models) and which will be installed on the Luxor Satellite Controllers (LSAT models). Primary Luxor Controllers are those with facepacks installed. Each LINK-MOD must be programmed at the primary controller prior to installation.

Step 1

Insert the Wireless Linking Module (LINK-MOD in the U.S. and Canada or LINK-MOD-E internationally) into either of the primary Luxor Controller linking ports.

Step 2

From the Home screen, use the scroll wheel to select Setup.

Step 3

Within the Setup screen, use the scroll wheel to select Linking.

Step 4

Scroll to the Chassis Number field and select 0 (Primary).

Step 5

Scroll to the Network ID field and select the desired Network ID (0–255). The Network ID will need to be configured the same on all Wireless Linking Modules installed on-site.

Step 6

Scroll to the Wireless Channel field and select the desired Wireless Channel (1–10). The channel will need to be configured the same on all Wireless Linking Modules installed on-site.

Step 7

Scroll to Program and press the scroll wheel.

Step 8

Assignment Succeeded will appear at the bottom of the screen. If the assignment fails, repeat the process. Remove the module from the linking port.