The CUBE requires a group number assignment for Luxor control. The default group number is one (1), but that number can be changed in one of two ways: 1) manual assignment at the Luxor assignment ports, or 2) wireless assignment via the Light Assignment Module (LAM).

MANUAL ASSIGNMENT AT LUXOR PORTS

Step
1

Insert Luxor wires into assignment ports. The lighting assignment screen is automatically displayed when the black CUBE wires (“LUX 1” and “LUX 2”) are inserted into the ports. This mode can also be forced by navigating to SETUP and selecting ASSIGN in the Luxor display menu. The CUBE wires must retain contact inside the assignment ports during the assignment process.

 

Step
2

Select group number. Use the scroll wheel to select the desired group number.

 

Step
3

Press PROGRAM. Navigate to PROGRAM and press the scroll wheel to initiate assignment. When complete, the screen will show “Assignment Successful” or “Assignment Failed.” If failed, reposition wires and try again. If the problem persists, the device may be defective.

Note: The assigned fixture group number is stored in the CUBE and not in the Luxor. Thus, power loss or other errors within the Luxor controller will not affect the assignment number. If the CUBE is replaced, the new CUBE must be assigned to the desired group number.

WIRELESS ASSIGNMENT WITH THE LAM

The CUBE is wirelessly assigned to a group number in the same manner as the integrated LED boards and ZD MR-16s lamps.

Click here and navigate to the "Using a LAM to Assign Fixtures to Group" section.