Read Article

Each recessed fixture includes a Schedule 40 conduit, which may be cut to length as needed. However, the conduit must always fully enclose the fixture base and must not be shorter than 7½ inches. Follow the step-by-step instructions below to install these lights. Insert the fixture module into the faceplate, and then press the complete assembly into the installed conduit. The module and faceplate must be fully pressed together to maintain a proper seal. Ensure the faceplate is pressed as flush as possible to the mounting surface.

Model Sleeve P/N SCH 40 Size Pipe OD Recommended Core Drill Size (using conduit sleeve) Recommended Core Drill Size (Not using the Conduit Sleeve)
PO 250018590000 1-1/2" 1.9" 2" 1-5/8''
VO C2165 N/A 1.78" (custom) 1-1/8" 1-3/4''
MO 25002060000 2" 2.36" 2-1/2" 2-1/8''
CG 250013670000 2" 2.375" 2-1/2" 2-1/8''
CN-51 N/A 2-1/2" 2.875" 3" 2-1/2''
CG-51 N/A 2-1/2" 2.875" 3" 2-1/2''

Step 1

Use the provided conduit and trim length if necessary.

Step 2

Install conduit sleeve into wall during construction. Run fixture wiring through sleeve. *Coupling for VO fixture only.

Step 3

Use voltmeter to ensure 11 to 15 V at fixture.

Step 4

Connect wiring with waterproof connector.

Step 5

Press faceplate into sleeve. Level and orient fixture as desired.

Step 6

* For the concrete ground-mount option, use construction housing. The VO-ST is rated for a load of 992 lbs.

Rate this Article: 